MF_020 - Wells and Pumps Monitoring
-
Monitoring Date
15-01-2017
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Juma Mape
-
Names of artisans involved in installing this well
Juma Mape
-
Pump producer Workshop
Ally
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Shiwinga secondary
-
Client Phone Number
0755071737
-
Installation Date
15-10-2017
-
Type of Client
School
-
Installed on
New Borehole
-
Depth (in metres)
18.50
-
GPS Coordinates{"latLng":[-8.970956, 32.944691], "data":"Submission", "tag":"text_2086", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Location: Province
Songwe
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Shiwinga
-
Drilling Techniques used
Rotter sludge sludge
-
Hand dug well (in centimetre)
Rotter sludge
-
Size
4
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
No
-
Is the water point currently functional?
Yes
-
If not, is water point repairable?
Yes
-
How many people use this water point?
400
-
How many Households use this water point?
1
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Secondary school funds
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Are casing and pump seals in well cover okay?
Yes
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
Water is contaminatated with few coliform so must be treated before drinking
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Other: Please explain in the box below
-
Other ways
Heifer project provide
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration method
-
Which apparatus were used in this method?
Forceps, MLSB saturation, hand pump, growth pads, incubator, petri dish etc.
-
Were faecal coliform present?
Yes
-
If present, how many?
1
-
Are they in allowable/ acceptable range?
No
-
If No, put your remarks
Pupils should not drink water before treated
-
Monitoring Date
15-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Juma workshop
-
Pump producer Workshop
Juma Mape
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Bernard sunguni
-
Client Address
Box 28 mbozi
-
Client Phone Number
0767752884
-
Installation Date
10-12-2017
-
Type of Client
Particular Household
-
Installed on
New well
-
Depth (in metres)
16
-
GPS Coordinates{"latLng":[-8.957836, 32.94707], "data":"Submission", "tag":"text_2055", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Location: Province
Songwe
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Shiwinga
-
Drilling Techniques used
Hand dug
-
What is the Diameter of the well/ tube well?
90
-
Hand dug well (in centimetre)
90
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
If not, is water point repairable?
Yes
-
How many people use this water point?
10
-
How many Households use this water point?
1
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking
-
Other water use, if any
Construction
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
The owner
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Not possible to see
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Are casing and pump seals in well cover okay?
Yes
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
No
-
Other remarks about the pump
Well is contaminated with few feacal
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Client found the name of the workshop/telephone number in an installed rope pump
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Total depth (in metres)
16
-
MAXIMUM WATER YIELD (in litters)
700
-
Want to perform Water Quality Test?
Yes
-
Which method did you use to test Faecal coliform?
Membrane filtration method
-
Which apparatus were used in this method?
Petri dishes, growth pads, forceps, MLSB saturation, hand pump, incubator,
-
Were faecal coliform present?
Yes
-
If present, how many?
2
-
Are they in allowable/ acceptable range?
No
-
Monitoring Date
15-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Uvinjo group
-
Pump producer Workshop
Uvinjo workshop
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Anold Mwalombe
-
Client Phone Number
0769994982
-
Installation Date
12-11-2017
-
Type of Client
Community
-
Installed on
New well
-
Depth (in metres)
8
-
GPS Coordinates{"latLng":[-8.89111, 33.060223], "data":"Submission", "tag":"text_1759", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Location: Province
Songwe
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Sambewe kati
-
Drilling Techniques used
Hand dug
-
What is the Diameter of the well/ tube well?
90
-
Hand dug well (in centimetre)
90
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
If not, is water point repairable?
No Answer
-
How many people use this water point?
400
-
How many Households use this water point?
66
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking
-
Other water use, if any
Construction
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Village government
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
No
-
Other remarks about the pump
Good yield
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Other: Please explain in the box below
-
Other ways
Heifer project provide
-
Take a picture of this activity
-
Add any overall comments/ remarks etc here
No coliform observed
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration method
-
Which apparatus were used in this method?
Petri dishes, growth pads, incubator, forceps, MLSB saturation, hand pump etc
-
Were faecal coliform present?
No
-
Are they in allowable/ acceptable range?
Yes
-
If No, put your remarks
Water is safe for drinking but well protection is needed
-
Monitoring Date
15-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Juma Mape
-
Names of artisans involved in installing this well
Juma Mape
-
Pump producer Workshop
Ally Fadhil
-
Well or Pump Serial number
2017/167
-
Pump Model
2
-
Name of Client
Williard Mwamengo
-
Client Phone Number
0767581663
-
Installation Date
15-11-2017
-
Type of Client
Community
-
Installed on
New well
-
Depth (in metres)
9
-
GPS Coordinates{"latLng":[-8.936047, 33.001409], "data":"Submission", "tag":"text_140", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Location: Province
Songwe
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Mpito A
-
Drilling Techniques used
Hand dug
-
What is the Diameter of the well/ tube well?
90
-
Hand dug well (in centimetre)
90
-
Hand dug well (in centimetre)
90
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
If not, is water point repairable?
No Answer
-
How many people use this water point?
300
-
How many Households use this water point?
50
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking
-
Other water use, if any
Construction
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Village government
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Are casing and pump seals in well cover okay?
Yes
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
Still operating
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Other: Please explain in the box below
-
Other ways
Heifer project provide
-
Take a picture of this activity
-
Add any overall comments/ remarks etc here
few bacteria observed, possibly because of poor supervisor of the well example washing clothes close to the well and animal feeding close the well
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Petri dishes, growth pads, incubator, forceps, MLSB saturation pads etc
-
Were faecal coliform present?
Yes
-
If present, how many?
1
-
Are they in allowable/ acceptable range?
No
-
If No, put your remarks
More protection of the well in needed
-
Monitoring Date
16-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Juma
-
Names of artisans involved in installing this well
Juma mape
-
Pump producer Workshop
Juma workshop
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Hatelele dispensary
-
Client Phone Number
0755797847
-
Installation Date
30-09-2017
-
Type of Client
Hospital
-
Installed on
New Borehole
-
Depth (in metres)
23
-
GPS Coordinates{"latLng":[-8.976683, 32.984571], "data":"Submission", "tag":"text_2204", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Hatelele
-
Tube well (in inches)
6
-
Size
6
-
Is the water point currently functional?
Yes
-
How many people use this water point?
500
-
How many Households use this water point?
20
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Watering animals
-
Other water use, if any
Sterilization of hospital equipments
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Community
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Are casing and pump seals in well cover okay?
Yes
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
No contamnation,
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Other: Please explain in the box below
-
Other ways
Heifer service provider
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Forceps, MLSB saturation, hand pump, incubator, petri dishes, growth pads
-
Were faecal coliform present?
No
-
Monitoring Date
16-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Uvinjo group
-
Names of artisans involved in installing this well
Laban
-
Pump producer Workshop
Uvinjo
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Wilson Havula
-
Client Phone Number
0755843429
-
Installation Date
06-12-2017
-
Type of Client
Community
-
Installed on
New well
-
Depth (in metres)
11
-
GPS Coordinates{"latLng":[-8.871281, 32.94699], "data":"Submission", "tag":"text_4196", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Location: Province
Songwe
-
Town
Iwalanje kamficheni
-
District
Mbozi
-
Neighborhood
Iwalanje kamficheni
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
How many people use this water point?
400
-
How many Households use this water point?
40
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
Well is contaminated with few coliform. Well is not covered with rope pump
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Other: Please explain in the box below
-
Other ways
Heifer service provider
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration method
-
Which apparatus were used in this method?
Forceps, MLSB saturation pads, hand pump, growth pads, incubator,
-
Were faecal coliform present?
Yes
-
If present, how many?
1
-
Are they in allowable/ acceptable range?
No
-
Monitoring Date
16-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Uvinjo group
-
Names of artisans involved in installing this well
Laban
-
Pump producer Workshop
Uvinjo
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Wilson Havula
-
Client Phone Number
0755843429
-
Installation Date
21-11-2017
-
Type of Client
Community
-
Installed on
New well
-
Depth (in metres)
17
-
GPS Coordinates{"latLng":[-8.865307, 32.950988], "data":"Submission", "tag":"text_698", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Location: Province
Songwe
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Iwalanje kati
-
Drilling Techniques used
Hand dug
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
No
-
How many people use this water point?
400
-
How many Households use this water point?
40
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
No
-
Are the users satisfied with the quantity of water obtained in the water point?
No
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Community
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
No
-
Size of the piston (in inches)
1/2"
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
No
-
Is the pump mounting okay?
No
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
No
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
No
-
Other remarks about the pump
No water in a well
-
How did the client get to know about ROPE PUMPS?
-
Take a picture of this activity
-
Monitoring Date
16-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Uvinjo group
-
Names of artisans involved in installing this well
Laban
-
Pump producer Workshop
Uvinjo workshop
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Lungwa village
-
Client Phone Number
0763441599
-
Installation Date
25-10-2017
-
Type of Client
Community
-
Installed on
New well
-
Depth (in metres)
6
-
GPS Coordinates{"latLng":[-8.879442, 33.004226], "data":"Submission", "tag":"text_3926", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Location: Province
Songwe
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Lungwa
-
Drilling Techniques used
Hand dug
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
How many people use this water point?
400
-
How many Households use this water point?
40
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Community
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
Well is contaminated with one fecal. Probably is secondary contamination
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Other: Please explain in the box below
-
Other ways
Heifer service provider
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Forceps, MLSB saturation, hand pump, growth pads, incubator, petri dish etc.
-
Were faecal coliform present?
Yes
-
If present, how many?
1
-
Are they in allowable/ acceptable range?
No
-
Monitoring Date
16-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Juma Mape
-
Names of artisans involved in installing this well
Juma Mape
-
Pump producer Workshop
Juma Mape
-
Well or Pump Serial number
2017/168
-
Pump Model
2
-
Name of Client
Nansama village
-
Client Phone Number
0769994982
-
Installation Date
30-11-2017
-
Type of Client
Community
-
Installed on
New well
-
Depth (in metres)
20
-
GPS Coordinates{"latLng":[-8.911068, 33.032466], "data":"Submission", "tag":"text_3639", "options":{"icon": "mobile"}, "accuracy":"5"}
-
Location: Province
Songwe
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Nansama
-
Drilling Techniques used
Hand dug
-
Is the water point currently functional?
Yes
-
How many people use this water point?
30
-
How many Households use this water point?
10
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Not known
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
River
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Community
-
Is the pump efficiency OK?
No
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Other remarks about the pump
The well was collapsed
-
How did the client get to know about ROPE PUMPS?
-
Take a picture of this activity
-
Monitoring Date
15-01-2018
-
Person Monitoring
Vincent Mgina
-
Installer Workshop
Uvinjo group
-
Names of artisans involved in installing this well
Villager community
-
Pump producer Workshop
Uvinjo workshop
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Igamba dispensary
-
Client Address
Uvinjo group
-
Client Phone Number
0755451135
-
Installation Date
09-09-2017
-
Type of Client
Hospital
-
Installed on
New Borehole
-
Depth (in metres)
27
-
GPS Coordinates{"latLng":[-8.991361, 32.923028], "data":"Submission", "tag":"text_89", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Location: Province
Songwe
-
Town
Mbozi
-
District
Mbozi
-
Neighborhood
Igamba
-
Drilling Techniques used
Rotter sludge
-
Size
4
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
No
-
Is the water point currently functional?
Yes
-
If not, is water point repairable?
Yes
-
How many people use this water point?
200
-
How many Households use this water point?
10
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Watering animals
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Stream
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Village government
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Are casing and pump seals in well cover okay?
Yes
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
Well is contaminated with few feacal
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Other: Please explain in the box below
-
Other ways
Heifer project provide
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration method
-
Which apparatus were used in this method?
Petri dishes, growth pads, forceps, hand pump, incubator, MLSB saturation pads etc .
-
Were faecal coliform present?
Yes
-
If present, how many?
1
-
Are they in allowable/ acceptable range?
No
-
Monitoring Date
18-01-2018
-
Person Monitoring
Vincent mgina
-
Installer Workshop
Kisangani group
-
Names of artisans involved in installing this well
Mose Mlowe
-
Pump producer Workshop
Electrical pump
-
Well or Pump Serial number
No
-
Pump Model
Submersible
-
Name of Client
Enock mpangile
-
Client Phone Number
0758763039
-
Installation Date
25-10-2017
-
Type of Client
Particular Household
-
Installed on
New well
-
Depth (in metres)
15
-
GPS Coordinates{"latLng":[-9.350035, 34.772907], "data":"Submission", "tag":"text_329", "options":{"icon": "mobile"}, "accuracy":"4"}
-
Town
Njombe
-
District
Njombe Town
-
Neighborhood
Mpechi Street
-
Drilling Techniques used
Hand dug
-
What is the Diameter of the well/ tube well?
90
-
Hand dug well (in centimetre)
90
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
How many people use this water point?
11
-
How many Households use this water point?
1
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Irrigation
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Njombe water supply
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Client
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Size of the piston (in inches)
1/2"
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
No
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
Rope pump was removed and replaced with submersible pump
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Client found the name of the workshop/telephone number in an installed rope pump
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Forceps, MLSB saturation pads, petri dishes, incubator, hand pump, membrane filtration pads etc.
-
Were faecal coliform present?
No
-
Are they in allowable/ acceptable range?
Yes
-
Monitoring Date
18-01-2018
-
Person Monitoring
Vincent mgina
-
Installer Workshop
Kisangani workshop
-
Names of artisans involved in installing this well
Mose Mlowe
-
Pump producer Workshop
Kisangani workshop
-
Well or Pump Serial number
No
-
Pump Model
2
-
Name of Client
Safarili
-
Client Phone Number
0767324628
-
Installation Date
13-11-2017
-
Type of Client
Business centres (Hotels, Lodges etc)
-
Installed on
New well
-
Depth (in metres)
9
-
GPS Coordinates{"latLng":[-9.393764, 34.815906], "data":"Submission", "tag":"text_3770", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Town
Njombe
-
District
Njombe Town
-
Neighborhood
Hagafilo Street
-
Drilling Techniques used
Hand dug
-
What is the Diameter of the well/ tube well?
90
-
Hand dug well (in centimetre)
90
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
How many people use this water point?
30
-
How many Households use this water point?
6
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Watering animals
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Njombe water supply
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Client
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
No
-
Is the rope OK?
No
-
Size of the piston (in inches)
1/2"
-
Are casing and pump seals in well cover okay?
Yes
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
No
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
Pump was removed because there are some people that fetch water without permission and damaged the pump
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Client found the name of the workshop/telephone number in an installed rope pump
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Forceps, MLSB saturation pads, petri dishes, incubator, hand pump, membrane filtration pads etc
-
Were faecal coliform present?
No
-
Are they in allowable/ acceptable range?
Yes
-
Monitoring Date
18-01-2018
-
Person Monitoring
Vincent mgina
-
Installer Workshop
Kisangani group
-
Names of artisans involved in installing this well
Moses
-
Pump producer Workshop
Kisangani workshop
-
Well or Pump Serial number
01120986
-
Pump Model
2
-
Name of Client
Martha
-
Client Address
VEO Idundilanga Street
-
Client Phone Number
0752329856
-
Installation Date
18-12-2017
-
Type of Client
Hospital
-
Installed on
New well
-
Depth (in metres)
10
-
GPS Coordinates{"latLng":[-9.349709, 34.769399], "data":"Submission", "tag":"text_911", "options":{"icon": "mobile"}, "accuracy":"4"}
-
Town
Njombe Town
-
District
Njombe
-
Neighborhood
Idundilanga
-
Hand dug well (in centimetre)
90
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
How many people use this water point?
300
-
How many Households use this water point?
15
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Others please explain below
-
Other water use, if any
Sterilisation of office equipments
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Njuwasa
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Community
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Yes
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
Operating well
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
I approached the client myself
-
Take a picture of this activity
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Forceps, MLSB saturation pads, petri dishes, incubator, hand pump, membrane filtration pads etc
-
Were faecal coliform present?
No
-
Are they in allowable/ acceptable range?
Yes
-
Monitoring Date
18-01-2018
-
Person Monitoring
Vincent mgina
-
Installer Workshop
Kisangani group
-
Names of artisans involved in installing this well
Mose Mlowe
-
Pump producer Workshop
Vijana group
-
Well or Pump Serial number
No
-
Pump Model
3
-
Name of Client
Christian kinyamagoha
-
Client Phone Number
0743969176
-
Installation Date
02-12-2017
-
Type of Client
Particular Household
-
Installed on
New well
-
Depth (in metres)
10
-
GPS Coordinates{"latLng":[-9.357681, 34.759437], "data":"Submission", "tag":"text_2105", "options":{"icon": "mobile"}, "accuracy":"5"}
-
Town
Njombe
-
District
Njombe Town
-
Neighborhood
Nzengerendete
-
Drilling Techniques used
Hand dug
-
Hand dug well (in centimetre)
90
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
If not, is water point repairable?
Yes
-
How many people use this water point?
7
-
How many Households use this water point?
2
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Others please explain below
-
Other water use, if any
Construction of building
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Njombe water supply
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
The client
-
Is the pump efficiency OK?
Yes
-
What is the size of the pump return pipe?
1/2''
-
Other size of pump return pipe
1"
-
Is guide block well installed?
Not possible to see
-
Is the rope OK?
Yes
-
Size of the piston (in inches)
1/2"
-
Is there a flat, wide enough space to put a bucket under the water exit?
Yes
-
Is the height of the pump handle okay?
Yes
-
Are the brushings properly oiled?
Yes
-
Is the pump mounting okay?
Yes
-
Are the concrete parts okay?
Yes
-
Are the apron and soak pit okay?
Yes
-
Is the pump functioning smoothly and pump water without friction?
Yes
-
Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?
Yes
-
Other remarks about the pump
It still operate no problem
-
Was the owner/ caretaker trained on the operation and maintenance of the pump?
Yes
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
Did you provide new motor oil for the bushings?
Yes
-
How did the client get to know about ROPE PUMPS?
Client found the name of the workshop/telephone number in an installed rope pump
-
Other ways
Construction
-
Take a picture of this activity
-
Add any overall comments/ remarks etc here
Well used for construction activities with neighbours.
-
What test do you want to perform?
Water Quality Test
-
Total depth (in metres)
10
-
MAXIMUM WATER YIELD (in litters)
1000
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Forceps, MLSB saturation pads, petri dishes, incubator, hand pump, membrane filtration pads etc
-
Were faecal coliform present?
No
-
Are they in allowable/ acceptable range?
Yes
-
Monitoring Date
16-11-2017
-
Person Monitoring
Eugenia Kimaro
-
Installer Workshop
Peramiho
-
Names of artisans involved in installing this well
Narzis Makukula and Nicodem Haule
-
Pump producer Workshop
No rope pump installed
-
Well or Pump Serial number
No
-
Pump Model
No
-
Name of Client
Neema
-
Client Phone Number
0752369658
-
Installation Date
21-08-2017
-
Type of Client
Particular Household
-
Installed on
New well
-
Depth (in metres)
13
-
GPS Coordinates{"latLng":[-10.608969, 35.455942], "data":"Submission", "tag":"text_2006", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Town
Songea
-
District
Peramiho
-
Neighborhood
Lundusi
-
Hand dug well (in centimetre)
100
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
No
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
No
-
Is the water point currently functional?
Yes
-
How many people use this water point?
1
-
How many Households use this water point?
1
-
What is the water used for?
Others please explain below
-
Other water use, if any
Construction of house
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Spring
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Owner
-
Other remarks about the pump
Well is not protected Tree logs is used to cover the well, so it at high risk for pollution during rain season. No safety
-
How did the client get to know about ROPE PUMPS?
I approached the client myself, Other: Please explain in the box below
-
Other ways
Well drilled by SHIPO is now usefull because all of the clients are beleaving after looking at the well in Lundusi Primary school
-
Take a picture of this activity
-
Add any overall comments/ remarks etc here
Client is advised to protect his well and he helped to know the benefit of it.
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Petri dishes, growth pads, hand pump, incubator, forceps , MLSB saturation, etc.
-
Were faecal coliform present?
No
-
Are they in allowable/ acceptable range?
Yes
-
Which apparatus were used in testing turbidity?
Turbid metre
-
What is the turbid level (in NTU)
6
-
Is the turbidity in allowable range?
No
-
Which method did you use to test PH?
Digital metre
-
Which apparatus were used in testing PH?
PH metre
-
What is the measure for PH test?
8
-
Is the PH in allowable range?
Yes
-
Monitoring Date
16-11-2017
-
Person Monitoring
Eugenia Kimaro
-
Installer Workshop
Peramiho group
-
Names of artisans involved in installing this well
Narzis Makukulala and Nicodem Haule
-
Pump producer Workshop
No
-
Well or Pump Serial number
No
-
Pump Model
No
-
Name of Client
Ima
-
Client Phone Number
0765329652
-
Installation Date
09-10-2017
-
Type of Client
Particular Household
-
Installed on
New well
-
Depth (in metres)
13
-
GPS Coordinates{"latLng":[-10.602153, 35.44273], "data":"Submission", "tag":"text_2097", "options":{"icon": "mobile"}, "accuracy":"1"}
-
Town
Songea
-
District
Peramiho
-
Neighborhood
Lundusi
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
No
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
No
-
Is the water point currently functional?
Yes
-
How many people use this water point?
2
-
How many Households use this water point?
1
-
What is the water used for?
Others please explain below
-
Other water use, if any
Construction of the house
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Spring
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Owner
-
Other remarks about the pump
No rope pump but apron is alread constructed client is on process to put rope pump
-
How did the client get to know about ROPE PUMPS?
I approached the client myself
-
Take a picture of this activity
-
Add any overall comments/ remarks etc here
Well is so wide which is lead unnecessary cost to the client Fundis are trained on issue and asked to prepare for 2018 update training so as they can improve Fundis are digging for free for promotion reasons
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Petri dish, hand pump, MLSB saturation pads, forceps, incubator
-
Were faecal coliform present?
No
-
Are they in allowable/ acceptable range?
Yes
-
Which apparatus were used in testing turbidity?
Turbid metre
-
What is the turbid level (in NTU)
5
-
Is the turbidity in allowable range?
Yes
-
Which method did you use to test PH?
Digital metre
-
Which apparatus were used in testing PH?
PH metre
-
What is the measure for PH test?
6.9
-
Is the PH in allowable range?
Yes
-
Monitoring Date
16-11-2017
-
Person Monitoring
Eugenia Kimaro
-
Installer Workshop
Peramiho
-
Names of artisans involved in installing this well
Narzis Makukula and Nicodem Haule
-
Pump producer Workshop
No rope pump installed
-
Well or Pump Serial number
No
-
Pump Model
No
-
Name of Client
Dickson Komba
-
Client Phone Number
0742889012
-
Installation Date
11-07-2017
-
Type of Client
Particular Household
-
Installed on
New well
-
Depth (in metres)
12
-
GPS Coordinates{"latLng":[-10.610672, 35.453014], "data":"Submission", "tag":"text_1888", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Town
Songea
-
District
Peramiho
-
Neighborhood
Lundusi
-
Hand dug well (in centimetre)
100
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
No
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
No
-
Is the water point currently functional?
Yes
-
How many people use this water point?
2
-
How many Households use this water point?
1
-
What is the water used for?
Others please explain below
-
Other water use, if any
Making bunt bricks
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Spring
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Owner
-
Other remarks about the pump
Well is not protected but client is trained the effects of protect his wells and he said it is in process.
-
How did the client get to know about ROPE PUMPS?
I approached the client myself
-
Take a picture of this activity
-
Add any overall comments/ remarks etc here
Fundis are now dig for free to promote themselves.
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Forceps, MLSB saturation pads, hand pump, growth pads, incubator, petri dish etc
-
Were faecal coliform present?
No
-
Are they in allowable/ acceptable range?
Yes
-
Which apparatus were used in testing turbidity?
Turbid metre
-
What is the turbid level (in NTU)
12
-
Is the turbidity in allowable range?
No
-
Which method did you use to test PH?
Digital metre
-
Which apparatus were used in testing PH?
PH metre
-
What is the measure for PH test?
7.5
-
Is the PH in allowable range?
Yes
-
Monitoring Date
16-11-2017
-
Person Monitoring
Eugenia Kimaro
-
Installer Workshop
Peramiho group
-
Names of artisans involved in installing this well
Narzis Makukula and Nicodem Haule
-
Pump producer Workshop
No rope pump installed
-
Well or Pump Serial number
No serial number
-
Pump Model
No
-
Name of Client
Mufti
-
Client Phone Number
0659769854
-
Installation Date
12-10-2017
-
Type of Client
Particular Household
-
Installed on
New well
-
Depth (in metres)
9
-
GPS Coordinates{"latLng":[-10.610169, 35.4506], "data":"Submission", "tag":"text_3076", "options":{"icon": "mobile"}, "accuracy":"1"}
-
Town
Songea
-
District
Peramiho
-
Neighborhood
Lundusi
-
Hand dug well (in centimetre)
100
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
No
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
No
-
Is the water point currently functional?
Yes
-
How many people use this water point?
4
-
How many Households use this water point?
1
-
What is the water used for?
Others please explain below
-
Other water use, if any
Making bricks for construction
-
Does the water point produce water during all seasons?
No
-
Are the users satisfied with the quantity of water obtained in the water point?
No
-
What other water sources will the users use if water points breaks?
Spring
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Owner
-
Other remarks about the pump
Well is unprotected also on top is covered with banana trees remains which is very risk for security Client is advised to put sign which will show that there is well in place so no one can accidentally fall in Also he promise to cover the well with pump and he is wait the brick which their now in burning process to be ready so as he can use them to construct apron
-
How did the client get to know about ROPE PUMPS?
I approached the client myself
-
Take a picture of this activity
-
Add any overall comments/ remarks etc here
As it is observed in picture, under the banana trees remains there is well. You can not notice which is very risk for security purpose.
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
Petri dishes, growth pads, forceps, MLSB saturation pads, hand pump, incubator, etc.
-
Were faecal coliform present?
No
-
If present, how many?
0
-
Are they in allowable/ acceptable range?
Yes
-
If No, put your remarks
Well should be covered because during rain season dirt water will run into a well and can even destruct the well due to erosion also pollution of water might occur.
-
Which apparatus were used in testing turbidity?
Turbid meter
-
What is the turbid level (in NTU)
9
-
Is the turbidity in allowable range?
No
-
If No, put your remarks
There many particals including insect inside
-
Which method did you use to test PH?
Digital metre
-
Which apparatus were used in testing PH?
PH metre
-
What is the measure for PH test?
8.2
-
Is the PH in allowable range?
Yes
-
Monitoring Date
16-11-2017
-
Person Monitoring
Eugenia Kimaro
-
Installer Workshop
Peramiho group
-
Names of artisans involved in installing this well
Narzis Makukula and Nicodem Haule
-
Pump producer Workshop
No pump
-
Well or Pump Serial number
No serial number
-
Pump Model
No rope pump installed
-
Name of Client
Lainel Haule
-
Client Phone Number
0765737639
-
Installation Date
14-08-2017
-
Type of Client
Particular Household
-
Installed on
New well
-
Depth (in metres)
9
-
GPS Coordinates{"latLng":[-10.613235, 35.453074], "data":"Submission", "tag":"text_3636", "options":{"icon": "mobile"}, "accuracy":"1"}
-
Town
Songea
-
District
Peramiho
-
Neighborhood
Lundusi
-
Hand dug well (in centimetre)
100
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
No
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
No
-
Is the water point currently functional?
Yes
-
If not, is water point repairable?
No Answer
-
How many people use this water point?
6
-
How many Households use this water point?
1
-
What is the water used for?
Domestic use (washing house, cloth, utensils), Personal hygiene, Others please explain below
-
Other water use, if any
Building construction
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Yes
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Spring
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Owner
-
Other remarks about the pump
Well is not iproved so very dangerous for health and security After educacation the owner promised to put rope pump Wellis so wide which will lead to unnecessary cost to the client and consume time for Fundi to complete activity. Fundi is asked to attend 2018 training for more training
-
How did the client get to know about ROPE PUMPS?
Other: Please explain in the box below
-
Other ways
Well demostrated by SHIPO in Lundus primary school
-
Take a picture of this activity
-
Add any overall comments/ remarks etc here
Fundi decided to dig 5 wells for free for market them selves Few ecol observed and this might be because the well is not protected so easy to be contaminated. So the coordinator provided the education about the effect of protect the well and he promise to do that.
-
What test do you want to perform?
Water Quality Test
-
Which method did you use to test Faecal coliform?
Membrane filtration
-
Which apparatus were used in this method?
MLSB saturation pads, forceps, hand pump, growth pads, incubator etc.
-
Were faecal coliform present?
Yes
-
If present, how many?
2
-
Are they in allowable/ acceptable range?
No
-
If No, put your remarks
Well should be protected to prevent fecol comtamination
-
Which apparatus were used in testing turbidity?
Turbid metre
-
What is the turbid level (in NTU)
10
-
Is the turbidity in allowable range?
No
-
If No, put your remarks
Well should be protected
-
Which method did you use to test PH?
Digital metre
-
Which apparatus were used in testing PH?
PH metre
-
What is the measure for PH test?
7.9
-
Is the PH in allowable range?
Yes
-
Monitoring Date
01-11-2017
-
Person Monitoring
Eugenia kimaro
-
Installer Workshop
Kisangani
-
Names of artisans involved in installing this well
Moses Mlowe
-
Pump producer Workshop
Kisangani
-
Well or Pump Serial number
Submersible pump
-
Pump Model
No
-
Name of Client
Ngailo
-
Client Phone Number
0763256921
-
Installation Date
26-09-2017
-
Type of Client
Other
-
If Other, write the type of client
Irigation of tomato in green house
-
Installed on
New well
-
Depth (in metres)
15
-
GPS Coordinates{"latLng":[-9.385164, 34.801354], "data":"Submission", "tag":"text_1596", "options":{"icon": "mobile"}, "accuracy":"2"}
-
Town
Njombe
-
District
Njombe Town
-
Neighborhood
Mji mwema
-
In a hand dug well, did you lined bricks 1.5 metres above water level?
Yes
-
In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?
Yes
-
Is the water point currently functional?
Yes
-
How many people use this water point?
2
-
How many Households use this water point?
1
-
What is the water used for?
Irrigation
-
Other water use, if any
Mainly for irrigation of tomato in a green house
-
Does the owner treat the water?
No
-
Does the water point produce water during all seasons?
Not known
-
Are the users satisfied with the quantity of water obtained in the water point?
Yes
-
What other water sources will the users use if water points breaks?
Neigbour well
-
If the water point breaks, will the users repair it?
Yes
-
If Yes, who will pay for the reparation?
Owner
-
Other remarks about the pump
No rope pump client is using submersible pump
-
Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?
Yes
-
How did the client get to know about ROPE PUMPS?
A friend/ neighbour/ family member indicated the client where to buy a rope pump
-
Take a picture of this activity