SKAT/ZH2O - Training 2020

MF_020 - Wells and Pumps Monitoring

ID #52236
Created: 2017-11-03 12:53:18
Edited: No
  • Monitoring Date

    30-10-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Kisangani

  • Names of artisans involved in installing this well

    Kelvin Mhagama

  • Pump producer Workshop

    No rope pump

  • Well or Pump Serial number

    No rope pump

  • Pump Model

    No

  • Name of Client

    Maximo Kyao

  • Client Phone Number

    0767326240

  • Installation Date

    24-08-2017

  • Type of Client

    Particular Household

  • If Other, write the type of client

    Construction of owner house

  • Installed on

    New well

  • Depth (in metres)

    13

  • GPS Coordinates
    {"latLng":[-9.358629, 34.795557], "data":"Submission", "tag":"text_2352", "options":{"icon": "mobile"}, "accuracy":"3"}
  • Town

    Njombe

  • District

    Njombe

  • Neighborhood

    Mkwezulu

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    No

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    3

  • How many Households use this water point?

    1

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Others please explain below

  • Other water use, if any

    Construction of house

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    Not known

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • What other water sources will the users use if water points breaks?

    River

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    No

  • Other remarks about the pump

    No rope pump in the well and this lead to the contamination of the well because water shows few colifom

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • How did the client get to know about ROPE PUMPS?

    A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • Add any overall comments/ remarks etc here

    Water is contaminated few coliforms observed

  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    9.5

  • Total depth (in metres)

    13

  • MAXIMUM WATER YIELD (in litters)

    120

  • Water level after pumping test (in metres)

    11

  • Water after 15 minutes of recovery time (in metres)

    10.5

  • Want to perform Water Quality Test?

    Yes

  • Which method did you use to test Faecal coliform?

    Membrane filtration

  • Which apparatus were used in this method?

    Forceps, MLSB saturation pads, hand pump, growth pads, petri dish etc

  • Were faecal coliform present?

    Yes

  • If present, how many?

    2

  • Are they in allowable/ acceptable range?

    No

  • If No, put your remarks

    Well is not well protected so it may be source of contaminination

  • Which method did you use to test PH?

    Digital meter

  • Which apparatus were used in testing PH?

    PH meter

  • What is the measure for PH test?

    8.7

  • Is the PH in allowable range?

    No

  • If No, put your remarks

    High temperature and suspect is cement because well is no much used.

ID #52235
Created: 2017-11-03 12:53:18
Edited: No
  • Monitoring Date

    03-11-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Umwaga investment

  • Names of artisans involved in installing this well

    Aliko Lunyungu

  • Pump producer Workshop

    Uvinjo group

  • Well or Pump Serial number

    2016/000143

  • Pump Model

    2

  • Name of Client

    Consolata mbwilo

  • Client Phone Number

    0762300063

  • Installation Date

    03-07-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    15

  • GPS Coordinates
    {"latLng":[-9.337291, 34.741623], "data":"Submission", "tag":"text_3199", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Njombe

  • District

    Njombe Town

  • Neighborhood

    Ramadhani

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    3

  • How many Households use this water point?

    1

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    No

  • Are the users satisfied with the quantity of water obtained in the water point?

    No

  • What other water sources will the users use if water points breaks?

    Neighbour well

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    No

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Water is finished after pumping of 240litres. Mr. Aliko will help the owner to increase the depth

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    13.2

  • Total depth (in metres)

    15

  • MAXIMUM WATER YIELD (in litters)

    200

  • Water level after pumping test (in metres)

    13.6

  • Water after 15 minutes of recovery time (in metres)

    13.6

ID #52234
Created: 2017-11-03 12:53:16
Edited: No
  • Monitoring Date

    30-10-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Ohad

  • Names of artisans involved in installing this well

    Ohad Ngulo

  • Pump producer Workshop

    SAM

  • Well or Pump Serial number

    2016/061

  • Pump Model

    2

  • Name of Client

    Amos Amon

  • Client Phone Number

    0752689290

  • Installation Date

    30-10-2017

  • Type of Client

    Particular Household

  • Installed on

    Existing well

  • Depth (in metres)

    20

  • GPS Coordinates
    {"latLng":[-9.351954, 34.798217], "data":"Submission", "tag":"text_802", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Njombe

  • District

    Njombe

  • Neighborhood

    Wende

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    No

  • If not, is water point repairable?

    No

  • How many people use this water point?

    0

  • How many Households use this water point?

    0

  • What is the water used for?

    Others please explain below

  • Other water use, if any

    Used few days for construction before dried

  • Does the water point produce water during all seasons?

    No

  • Are the users satisfied with the quantity of water obtained in the water point?

    No

  • What other water sources will the users use if water points breaks?

    River

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Is the pump efficiency OK?

    No

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    No

  • Is the pump functioning smoothly and pump water without friction?

    No

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Well is dried and client decided to use trained artisans from SHIPO to start new well with new contract

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    No

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    No

  • Did you provide new motor oil for the bushings?

    No

  • How did the client get to know about ROPE PUMPS?

    Other: Please explain in the box below

  • Other ways

    Client knew the artisans and technology very long time

  • Take a picture of this activity
    Take a picture of this activity
ID #52233
Created: 2017-11-03 12:53:09
Edited: No
  • Monitoring Date

    03-11-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Umwaga investment

  • Names of artisans involved in installing this well

    Aliko Lunyungu

  • Pump producer Workshop

    Uvinjo group

  • Well or Pump Serial number

    2016/0081

  • Pump Model

    2

  • Name of Client

    Anna Mzeru

  • Client Phone Number

    0755926425

  • Installation Date

    06-09-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    20

  • GPS Coordinates
    {"latLng":[-9.368004, 34.814561], "data":"Submission", "tag":"text_4022", "options":{"icon": "mobile"}, "accuracy":"3"}
  • Town

    Njombe

  • District

    Njombe Town

  • Neighborhood

    Msete

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    17

  • How many Households use this water point?

    3

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking

  • Does the water point produce water during all seasons?

    Not known

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • What other water sources will the users use if water points breaks?

    River

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Good yield

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    18.6

  • Total depth (in metres)

    20

  • MAXIMUM WATER YIELD (in litters)

    200

  • Water level after pumping test (in metres)

    19.01

  • Water after 15 minutes of recovery time (in metres)

    19.01

ID #52232
Created: 2017-11-03 12:50:06
Edited: No
  • Monitoring Date

    01-11-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Wagumu

  • Names of artisans involved in installing this well

    Kelvin Mhagama

  • Pump producer Workshop

    No pump

  • Well or Pump Serial number

    No

  • Pump Model

    No

  • Name of Client

    Mama rich

  • Client Phone Number

    0763638786

  • Installation Date

    03-06-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    13

  • GPS Coordinates
    {"latLng":[-9.363725, 34.801638], "data":"Submission", "tag":"text_4604", "options":{"icon": "mobile"}, "accuracy":"1"}
  • Town

    Njombe

  • District

    Njombe Town

  • Neighborhood

    Wende

ID #52231
Created: 2017-11-03 12:44:31
Edited: No
  • Monitoring Date

    30-10-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Kisangani

  • Names of artisans involved in installing this well

    Moses Mlowe

  • Pump producer Workshop

    Kisangani

  • Well or Pump Serial number

    2017/2701

  • Pump Model

    2

  • Name of Client

    Sister Anneth

  • Client Phone Number

    0763493841

  • Installation Date

    26-06-2017

  • Type of Client

    Other

  • If Other, write the type of client

    Irigation

  • Installed on

    New well

  • Depth (in metres)

    15

  • GPS Coordinates
    {"latLng":[-9.375467, 34.988354], "data":"Submission", "tag":"text_4873", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Njombe

  • District

    Njombe Town

  • Neighborhood

    Idunda

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    3

  • How many Households use this water point?

    1

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Irrigation

  • Other water use, if any

    Main reasons to have a well is to use for irrigation of avocado farm

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    Yes

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • What other water sources will the users use if water points breaks?

    Other well

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    A well has good yield and it is combination of rope pump and submersible pump

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    9.6

  • Total depth (in metres)

    15

  • MAXIMUM WATER YIELD (in litters)

    480

  • Water level after pumping test (in metres)

    10.01

  • Water after 15 minutes of recovery time (in metres)

    9.89

ID #52230
Created: 2017-11-03 12:44:30
Edited: No
  • Monitoring Date

    30-10-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Kisangani

  • Names of artisans involved in installing this well

    Mose Mlowe

  • Pump producer Workshop

    Kisangani

  • Well or Pump Serial number

    2017/2705

  • Pump Model

    2

  • Name of Client

    Albert Paula

  • Client Phone Number

    0768300385

  • Installation Date

    25-08-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    20

  • GPS Coordinates
    {"latLng":[-9.348424, 34.801476], "data":"Submission", "tag":"text_3029", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Njombe

  • District

    Njombe

  • Neighborhood

    Wende

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    No

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    15

  • How many Households use this water point?

    3

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Irrigation, Others please explain below

  • Other water use, if any

    House construction

  • Does the owner treat the water?

    No

  • How?

    Only neighbours fetching water

  • Does the water point produce water during all seasons?

    Not known

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • What other water sources will the users use if water points breaks?

    River

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    No

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    No

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Good yield

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    Client saw a flier/ catalogue/ printed publicity of SMART solutions

  • Take a picture of this activity
    Take a picture of this activity
  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    12.9

  • Total depth (in metres)

    20

  • MAXIMUM WATER YIELD (in litters)

    320

  • Water level after pumping test (in metres)

    13.8

  • Water after 15 minutes of recovery time (in metres)

    13.4

  • Want to perform Water Quality Test?

    Yes

  • Which method did you use to test Faecal coliform?

    Membrane filtration

  • Which apparatus were used in this method?

    Forceps, MLSB saturation pads, hand pump, growth pads, petri dish etc

  • Were faecal coliform present?

    No

  • If present, how many?

    0

  • Are they in allowable/ acceptable range?

    Yes

  • If No, put your remarks

    No problem about quality of water

  • Which method did you use to test PH?

    Digital metre

  • Which apparatus were used in testing PH?

    PH metre

  • What is the measure for PH test?

    7.9

  • Is the PH in allowable range?

    Yes

  • If No, put your remarks

    Good

ID #52229
Created: 2017-11-03 12:44:30
Edited: No
  • Monitoring Date

    01-11-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Kisangani

  • Names of artisans involved in installing this well

    Mose Mlowe

  • Pump producer Workshop

    Kisangani

  • Well or Pump Serial number

    No

  • Pump Model

    2

  • Name of Client

    Eniat Mtweve

  • Client Phone Number

    0757057917

  • Installation Date

    30-10-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    15

  • GPS Coordinates
    {"latLng":[-9.362906, 34.754568], "data":"Submission", "tag":"text_1764", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Njombe

  • District

    Njombe

  • Neighborhood

    Kambarage

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    No

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    2

  • How many Households use this water point?

    1

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Irrigation

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    Not known

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • What other water sources will the users use if water points breaks?

    Other well from neighbour

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Not possible to see

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    No

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Well was colapse and client decided to use trained artisan trained by SHIPO To drill new well

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    Client found the name of the workshop/telephone number in an installed rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • Add any overall comments/ remarks etc here

    Good yield

  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    12.5

  • Total depth (in metres)

    15

  • MAXIMUM WATER YIELD (in litters)

    280

  • Water level after pumping test (in metres)

    12.96

  • Water after 15 minutes of recovery time (in metres)

    12.8

ID #52228
Created: 2017-11-03 12:44:30
Edited: No
  • Monitoring Date

    01-11-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Kisangani

  • Names of artisans involved in installing this well

    Mose

  • Pump producer Workshop

    Kisangani

  • Well or Pump Serial number

    2017/2708

  • Pump Model

    2

  • Name of Client

    Mama laban

  • Client Phone Number

    0752038240

  • Installation Date

    23-06-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    26

  • GPS Coordinates
    {"latLng":[-9.373769, 34.81011], "data":"Submission", "tag":"text_2754", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Njombe

  • District

    Njombe Town

  • Neighborhood

    Msete

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    12

  • How many Households use this water point?

    3

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Others please explain below

  • Other water use, if any

    Constrution

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    Not known

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • What other water sources will the users use if water points breaks?

    Neighbour well

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Good yield

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    20.8

  • Total depth (in metres)

    26

  • MAXIMUM WATER YIELD (in litters)

    280

  • Water level after pumping test (in metres)

    21

  • Water after 15 minutes of recovery time (in metres)

    20.8

ID #52227
Created: 2017-11-03 12:44:30
Edited: No
  • Monitoring Date

    01-11-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Wagumu

  • Names of artisans involved in installing this well

    Kelvin Mhagama

  • Pump producer Workshop

    No rope pump

  • Well or Pump Serial number

    No

  • Pump Model

    No

  • Name of Client

    Prosper Mfugale

  • Client Phone Number

    0766880828

  • Installation Date

    28-08-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    16

  • GPS Coordinates
    {"latLng":[-9.412803, 34.828885], "data":"Submission", "tag":"text_3803", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Njombe

  • District

    Njombe Town

  • Neighborhood

    Nundu

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    No

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    3

  • How many Households use this water point?

    1

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    Yes

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • What other water sources will the users use if water points breaks?

    Neighbour well

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Owner

  • Other remarks about the pump

    Well is not installed with rope pump, also toilet is very close to the well so client is advice to remove the toilet because it was built after well has been constructed

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • How did the client get to know about ROPE PUMPS?

    Other: Please explain in the box below

  • Other ways

    Artisan and client are relatives

  • Take a picture of this activity
    Take a picture of this activity
ID #50066
Created: 2017-10-04 13:21:00
Edited: No
  • Monitoring Date

    27-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Mshindo

  • Names of artisans involved in installing this well

    Daud Mshindo

  • Pump producer Workshop

    SAM

  • Well or Pump Serial number

    2017/056

  • Pump Model

    2

  • Name of Client

    Igomtwa primary school

  • Client Phone Number

    0757796492

  • Installation Date

    10-01-2017

  • Type of Client

    School

  • Installed on

    New well

  • Depth (in metres)

    11

  • GPS Coordinates
    {"latLng":[-8.220365, 35.596366], "data":"Submission", "tag":"text_3276", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Igomtwa

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • If not, is water point repairable?

    Yes

  • How many people use this water point?

    400

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking

  • Does the owner treat the water?

    Yes

  • How?

    Waterguard

  • Does the water point produce water during all seasons?

    Yes

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • What other water sources will the users use if water points breaks?

    River_very dirt water

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    School

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    No any problem declared by client, good well water yield

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    I approached the client myself, A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    10.7

  • Total depth (in metres)

    11

  • MAXIMUM WATER YIELD (in litters)

    290

  • Water level after pumping test (in metres)

    11.2

  • Water after 15 minutes of recovery time (in metres)

    11.1

ID #50065
Created: 2017-10-04 13:17:55
Edited: No
  • Monitoring Date

    27-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Mshindo

  • Names of artisans involved in installing this well

    Daud Mshindo

  • Pump producer Workshop

    Bosco Mbembe

  • Well or Pump Serial number

    No

  • Pump Model

    2

  • Name of Client

    Elia Mage

  • Client Phone Number

    0762759510

  • Installation Date

    01-08-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    9

  • GPS Coordinates
    {"latLng":[-8.219915, 35.591077], "data":"Submission", "tag":"text_4237", "options":{"icon": "mobile"}, "accuracy":"6"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Igomtwa

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • What is the water used for?

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1/4"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    No

  • Other remarks about the pump

    Poor quality pump, owner was not present so not possible to get all answers

  • How did the client get to know about ROPE PUMPS?

  • Take a picture of this activity
    Take a picture of this activity
ID #50064
Created: 2017-10-04 13:17:52
Edited: No
  • Monitoring Date

    27-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Rahajene

  • Names of artisans involved in installing this well

    Christopher Sanga, Naftal Cheles

  • Pump producer Workshop

    Bosco Mbembe

  • Well or Pump Serial number

    No

  • Pump Model

    2

  • Name of Client

    TEACHER KIWELE

  • Client Phone Number

    0754872721

  • Installation Date

    14-08-2017

  • Type of Client

    Other

  • If Other, write the type of client

    Domitory

  • Installed on

    Existing well

  • GPS Coordinates
    {"latLng":[-8.306965, 35.272201], "data":"Submission", "tag":"text_53", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Changarewe

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    78

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking

  • Does the owner treat the water?

    Yes

  • Does the water point produce water during all seasons?

    Not known

  • Are the users satisfied with the quantity of water obtained in the water point?

    No

  • What other water sources will the users use if water points breaks?

    Other well

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Teacher Kiwele

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1/4"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Are casing and pump seals in well cover okay?

    Yes

  • Is there a flat, wide enough space to put a bucket under the water exit?

    No

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    No

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    No

  • Are the apron and soak pit okay?

    No

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    No

  • Other remarks about the pump

    Well is not well installed because the client is using untrained people to dig so challenge to repair when broken Poor quality pump

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    No

  • How did the client get to know about ROPE PUMPS?

    A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • Add any overall comments/ remarks etc here

    Water is finished after 14 min and 180liters

  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    9.72

  • Total depth (in metres)

    12

  • MAXIMUM WATER YIELD (in litters)

    180

  • Water level after pumping test (in metres)

    9.72

  • Water after 15 minutes of recovery time (in metres)

    9.7

ID #50063
Created: 2017-10-04 13:17:52
Edited: No
  • Monitoring Date

    27-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Rahajene

  • Names of artisans involved in installing this well

    Christopher Sanga, Naftal Cheles

  • Pump producer Workshop

    Bosco Mbembe

  • Well or Pump Serial number

    No

  • Pump Model

    2

  • Name of Client

    Afande Zamda

  • Client Phone Number

    0757253667

  • Installation Date

    18-03-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    6

  • GPS Coordinates
    {"latLng":[-8.288795, 35.271174], "data":"Submission", "tag":"text_4101", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Ostabey

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    No

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • If not, is water point repairable?

    Yes

  • How many people use this water point?

    7

  • How many Households use this water point?

    1

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    Yes

  • Are the users satisfied with the quantity of water obtained in the water point?

    Yes

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Afande Zamda

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Good yield

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    I approached the client myself, A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    4

  • Total depth (in metres)

    5

  • MAXIMUM WATER YIELD (in litters)

    280

  • Water level after pumping test (in metres)

    4.36

  • Water after 15 minutes of recovery time (in metres)

    4.33

ID #50062
Created: 2017-10-04 13:16:51
Edited: No
  • Monitoring Date

    27-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Rahajene

  • Names of artisans involved in installing this well

    Christopher Sanga, Regan

  • Pump producer Workshop

    Copycats

  • Well or Pump Serial number

    No

  • Pump Model

    2

  • Name of Client

    Afande Hasan

  • Client Phone Number

    07555400064

  • Installation Date

    08-09-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    14

  • GPS Coordinates
    {"latLng":[-8.279842, 35.275287], "data":"Submission", "tag":"text_4398", "options":{"icon": "mobile"}, "accuracy":"3"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Ihongole

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • What is the water used for?

  • Is the pump efficiency OK?

    No

  • Other remarks about the pump

    Well has been dried, pump was not in SHIPO standard it was made by copycat Housemaid was in the house and she refused to provide information

  • How did the client get to know about ROPE PUMPS?

  • Take a picture of this activity
    Take a picture of this activity
ID #50061
Created: 2017-10-04 13:16:50
Edited: No
  • Monitoring Date

    27-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Rahajene

  • Names of artisans involved in installing this well

    Christopher Sanga, Naftal Cheles

  • Pump producer Workshop

    Bosco mbembe

  • Well or Pump Serial number

    No

  • Pump Model

    2

  • Name of Client

    God bless Nyongole

  • Client Phone Number

    0653201532

  • Installation Date

    02-08-2017

  • Type of Client

    Particular Household

  • Installed on

    Existing well

  • Depth (in metres)

    9

  • GPS Coordinates
    {"latLng":[-8.275727, 35.28792], "data":"Submission", "tag":"text_2959", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Ihongole

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • What is the water used for?

  • Does the water point produce water during all seasons?

    Not known

  • Other remarks about the pump

    Owner was not present in house

  • How did the client get to know about ROPE PUMPS?

  • Take a picture of this activity
    Take a picture of this activity
  • Add any overall comments/ remarks etc here

    No people in house so failed to get the information

ID #50060
Created: 2017-10-04 13:16:50
Edited: No
  • Monitoring Date

    27-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    SAM

  • Names of artisans involved in installing this well

    Naftal Cheles, Regan

  • Pump producer Workshop

    SAM

  • Well or Pump Serial number

    2017/022

  • Pump Model

    2

  • Name of Client

    Mhagama

  • Client Phone Number

    0752636526

  • Installation Date

    28-01-2017

  • Type of Client

    Particular Household

  • Installed on

    New well

  • Depth (in metres)

    13

  • GPS Coordinates
    {"latLng":[-8.276742, 35.278015], "data":"Submission", "tag":"text_3802", "options":{"icon": "mobile"}, "accuracy":"1"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Ihongole

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • What is the water used for?

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Not possible to get answer from user side because there was no someone in house

  • How did the client get to know about ROPE PUMPS?

  • Take a picture of this activity
    Take a picture of this activity
ID #50059
Created: 2017-10-04 13:16:45
Edited: No
  • Monitoring Date

    26-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Rahejene

  • Names of artisans involved in installing this well

    Christopher Sanga, Naftal Cheles

  • Pump producer Workshop

    Kisangani

  • Well or Pump Serial number

    2017/2707

  • Pump Model

    2

  • Name of Client

    Wogofya

  • Installation Date

    27-06-2017

  • Type of Client

    Business centres (Hotels, Lodges etc)

  • Installed on

    New well

  • Depth (in metres)

    13

  • GPS Coordinates
    {"latLng":[-8.281821, 35.304634], "data":"Submission", "tag":"text_3252", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Kinyanambo A

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • If not, is water point repairable?

    Yes

  • How many people use this water point?

    20

  • How many Households use this water point?

    5

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    Yes

  • Are the users satisfied with the quantity of water obtained in the water point?

    No

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1"

  • Are casing and pump seals in well cover okay?

    Yes

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    No enough water, Rahajene group will increase the depth

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    No

  • How did the client get to know about ROPE PUMPS?

    I approached the client myself, A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • Add any overall comments/ remarks etc here

    He likes technology, he has like 6 well, he is thinking to start car washing

  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    14.03

  • Total depth (in metres)

    15

  • MAXIMUM WATER YIELD (in litters)

    200

  • Water level after pumping test (in metres)

    14.9

  • Water after 15 minutes of recovery time (in metres)

    14.9

ID #50058
Created: 2017-10-04 13:16:44
Edited: No
  • Monitoring Date

    26-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Rahajene

  • Names of artisans involved in installing this well

    Christopher Sanga, Naftal Cheles

  • Pump producer Workshop

    Kisangani

  • Well or Pump Serial number

    2017/2708

  • Pump Model

    2

  • Name of Client

    Afande Mwakibolwa

  • Client Phone Number

    0756611199

  • Installation Date

    12-06-2017

  • Type of Client

    Particular Household

  • GPS Coordinates
    {"latLng":[-8.270869, 35.30601], "data":"Submission", "tag":"text_1831", "options":{"icon": "mobile"}, "accuracy":"1"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Kinyanambo A

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • How many people use this water point?

    15

  • How many Households use this water point?

    4

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Others please explain below

  • Other water use, if any

    Construction

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    No

  • Are the users satisfied with the quantity of water obtained in the water point?

    No

  • What other water sources will the users use if water points breaks?

    Neighbours

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Mwakibolwa

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Are casing and pump seals in well cover okay?

    Yes

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    No

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    Yes

  • Are the apron and soak pit okay?

    Yes

  • Is the pump functioning smoothly and pump water without friction?

    No

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    No caretaker for the well No enough water, depth should be incresed

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    No

  • How did the client get to know about ROPE PUMPS?

    I approached the client myself, A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Take a picture of this activity
    Take a picture of this activity
  • Add any overall comments/ remarks etc here

    No enough water

  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    10.63

  • Total depth (in metres)

    11

  • MAXIMUM WATER YIELD (in litters)

    200

  • Water level after pumping test (in metres)

    10.9

  • Water after 15 minutes of recovery time (in metres)

    10.9

ID #50057
Created: 2017-10-04 13:13:25
Edited: No
  • Monitoring Date

    26-09-2017

  • Person Monitoring

    Eugenia Kimaro

  • Installer Workshop

    Rahajene

  • Names of artisans involved in installing this well

    Christopher Sanga, Naftal cheles

  • Pump producer Workshop

    Bosco mbembe

  • Well or Pump Serial number

    2017/212

  • Pump Model

    2

  • Name of Client

    Damas Ng'umbi

  • Client Phone Number

    0755055043

  • Installation Date

    21-09-2017

  • Type of Client

    Business centres (Hotels, Lodges etc)

  • Installed on

    New well

  • Depth (in metres)

    12

  • GPS Coordinates
    {"latLng":[-8.250172, 35.3536], "data":"Submission", "tag":"text_4689", "options":{"icon": "mobile"}, "accuracy":"2"}
  • Town

    Mafinga

  • District

    Mufindi

  • Neighborhood

    Kinyanambo C

  • In a hand dug well, did you lined bricks 1.5 metres above water level?

    Yes

  • In a hand dug well, is a reducer installed to 0.8 - 0.9 m diameter?

    Yes

  • Is the water point currently functional?

    Yes

  • If not, is water point repairable?

    Yes

  • How many people use this water point?

    3

  • How many Households use this water point?

    3

  • What is the water used for?

    Domestic use (washing house, cloth, utensils), Personal hygiene, Drinking, cooking, Others please explain below

  • Other water use, if any

    Cooling of machines

  • Does the owner treat the water?

    No

  • Does the water point produce water during all seasons?

    Not known

  • Are the users satisfied with the quantity of water obtained in the water point?

    No

  • What other water sources will the users use if water points breaks?

    River

  • If the water point breaks, will the users repair it?

    Yes

  • If Yes, who will pay for the reparation?

    Damas Ng'umbi

  • Is the pump efficiency OK?

    Yes

  • What is the size of the pump return pipe?

    1/2''

  • Other size of pump return pipe

    1/2"

  • Is guide block well installed?

    Yes

  • Is the rope OK?

    Yes

  • Size of the piston (in inches)

    1/2"

  • Is there a flat, wide enough space to put a bucket under the water exit?

    Yes

  • Is the height of the pump handle okay?

    Yes

  • Are the brushings properly oiled?

    Yes

  • Is the pump mounting okay?

    Yes

  • Are the concrete parts okay?

    No

  • Are the apron and soak pit okay?

    No

  • Is the pump functioning smoothly and pump water without friction?

    Yes

  • Is phone number painted in the rope pump and the date of installation and the name of your workshop written in the apron?

    Yes

  • Other remarks about the pump

    Concrete ratio not very good

  • Was the owner/ caretaker trained on the operation and maintenance of the pump?

    Yes

  • Was the owner provided with the warranty document and explained the conditions of the warranty to the client and provided telephone number so they can call for reparations?

    Yes

  • Did you provide new motor oil for the bushings?

    Yes

  • How did the client get to know about ROPE PUMPS?

    I approached the client myself, A friend/ neighbour/ family member indicated the client where to buy a rope pump

  • Add any overall comments/ remarks etc here

    Well dried after pumping of 100liters, entrepreneur will go back 1st week of October to increase depth of the well

  • What test do you want to perform?

    Pump Test

  • Static water level (in metres) - above/bottom

    10.06

  • Total depth (in metres)

    13

  • MAXIMUM WATER YIELD (in litters)

    100

  • Water level after pumping test (in metres)

    10.20

  • Water after 15 minutes of recovery time (in metres)

    10.20

  • Want to perform Water Quality Test?

    Yes

  • Which method did you use to test Faecal coliform?

    Membrane filtration method

  • Which apparatus were used in this method?

    Petri dish, growth pads,MLSB saturation pads, hand pump,forceps etc

  • Were faecal coliform present?

    Yes

  • If present, how many?

    2

  • Are they in allowable/ acceptable range?

    No

  • If No, put your remarks

    Water should be treated before drinking

  • Which turbidity method did you use?

    5

  • Which apparatus were used in testing turbidity?

    Turbid metre

  • What is the turbid level (in NTU)

    5

  • Is the turbidity in allowable range?

    Yes

  • Which method did you use to test PH?

    Digital meter

  • Which apparatus were used in testing PH?

    PH metre-Wagtech

  • What is the measure for PH test?

    7.7

  • Is the PH in allowable range?

    Yes

Lost your password?